Richmond water heater pilot light won - Press and hold down on the gas control knob, or pilot set button. At the same time as you’re holding down the pilot switch, press on the piezo igniter. When you click the igniter, you should hear a “click” sound, indicating the spark igniting the pilot. Once the pilot light is on, continue pressing down on the pilot switch for a minute to ...

 
For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long life. Houses for rent in albuquerque under dollar900

If the pilot won't stay lit after you release the button/knob you hold down to light it then the first thing that needs to be done is to replace the pilot flame sensor, thermocouple (heavy bare copper wire connected to the gas valve) or the thermopile (small shielded cable with 2 wires connected to the gas valve).It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.Jun 10, 2022 · It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c... A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ... Water heater pilot won't light. Richmond water heater, smelled for gas at end of tibe by burner and is present. Filter - Answered by a verified HVAC TechnicianA water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ...Usually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ...Remove the access panel to access the burner. Turn the knob to “Pilot” to start the flow of gas. You’ll want to press and hold the knob down. While still holding the gas knob, light the pilot with a long lighter. If your gas water heater has an igniting button, press that instead. Once ignited, release and turn the gas knob to the “On ...I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit.Slightly depress the gas control knob and turn clockwise to OFF position. Wait 5 minutes to clear out any gas. Stop and follow the safety precautions as above if you smell any gas. Go to the next step if you do not smell gas. Remove the outer door from the water heater. Do not attempt to remove the inner door.The pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m …Apr 24, 2011 · I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit. If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ...Press and hold down on the gas control knob, or pilot set button. At the same time as you’re holding down the pilot switch, press on the piezo igniter. When you click the igniter, you should hear a “click” sound, indicating the spark igniting the pilot. Once the pilot light is on, continue pressing down on the pilot switch for a minute to ...I have a Richmond electronic iginition water heater model 5VP40E-1A, sometimes it lights and and works for a few days, sometimes I have to shut it down and then re-start it to get it to work, seen oth …richmond tankless gas hot water heater won't run. under the panel the red light was blinking 6 times. But now it is blinking constantly. Before it stopped working, the exhaust vent was clogged with sn …It’s also a relatively inexpensive component. So, you won’t have to break the bank to replace it. You can check out our guide on why Richmond water heater pilot light won’t stay lit where we have broken down how to replace the thermocouple in nice and easy steps. 6. Faulty Pressure SwitchWe have a Rheem gas water heater model number 21V40-7P. We've just gotten the gas tank refilled, but for some reason, the pilot light went out this morning and the water heater is leaking. I'm trying … read moreA water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ... Dec 8, 2016 · I have a Richmond rmtgl74pvn tankless water heater that has worked great for5 years but it stopped working just now. Won't light, looks like there is no power to the board but I've checked that. read more Usually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup the …1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions for lighting do not match my heater: I see no door to open; no place to see the pilot to determine if it's litDec 4, 2018 · Find Thermo couopler for your Water Heater Here: https://www.repairclinic.com/Shop-For-Parts?query=water%20heater%20thermo%20coupleGas water heater pilot not... Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … read moreI had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.Jan 17, 2021 · I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read more Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Feb 15, 2021 · If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ... The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article.If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ...Nov 28, 2009 · RickyM1118. Plumber. High School or GED. 29 satisfied customers. My seven year old Richmond 6G40-32PF1 lp gas water heater. My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after releasing button. The gas tank ran out of gas and was … read more. Apr 12, 2021 · 6. Below is a picture of the lighting instructions for your water heater taken from Rheem's website. Make sure to follow the lighting instructions carefully and do not skip any steps. This same instruction set should be available as a sticker on your unit. It looks like you do in fact have to depress the knob in order to turn it so avoid using ... 01 - Water Heater Gas Valve and Thermostat Assembly. The gas valve opens to allow gas to enter the burner. If the gas valve does not open, the burner will not light. First, ensure that the ignition source is working properly. Second, ensure that the gas valve has pressure. If the ignition source is working, and the gas valve has pressure ... Richmond water heater, pilot light won’t remain on, 6G40-36F1, Yesterday - pilot went out, relighted the pilot, pilot - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.Access the pilot light: Depending on the model of your water heater, you may need to remove a metal panel to access the pilot light. Once you have access, locate the pilot light and the reset button. Press the reset button: Press and hold the reset button for 30-60 seconds.A thermocouple is a function on your water heater that senses the heat on the pilot light and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner, which is when people notice that the water heater pilot light is out. Your water heater pilot light works in concert with other parts.A thermocouple is a function on your water heater that senses the heat on the pilot light and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner, which is when people notice that the water heater pilot light is out. Your water heater pilot light works in concert with other parts.The pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air Conditioning Mar 8, 2010 · Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ... I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read moreThe pilot light is an essential part of your Rheem water heater. If it goes out, your water heater wont provide any heat because the pilot light wont ignite the gas to power the heater. This means that you wont be able to light your pilot light. One potential cause of this issue is that you have a blocked gas line.Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ...Slightly depress the gas control knob and turn clockwise to OFF position. Wait 5 minutes to clear out any gas. Stop and follow the safety precautions as above if you smell any gas. Go to the next step if you do not smell gas. Remove the outer door from the water heater. Do not attempt to remove the inner door.If your pilot light on your Richmond water heater won’t stay lit, it’s usually due to a faulty thermocouple or a lack of combustible air. A problem with the thermocouple is significantly more common, but both could be causing problems. Today, we’ll examine why your water heater pilot light keeps going out and discuss ways you can fix it. The Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need. Clean those first before doing anything else. It's routine maintenance that needs to be done in any case. You need to remove the pilot burner, take the pilot tubing off and remove the pilot orifice. Sometimes you can clean the pilot orifice with the wire from a wire brush. Use a wire brush to clean the pilot burner.By Vikram May 7, 2023 If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won’t stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them.Sep 25, 2021 · Have you tried cleaning/replacing your thermocouple and still no dice? Have you tried cleaning/replacing the pilot assembly and still nothing? My opinion is ... Dec 8, 2016 · I have a Richmond rmtgl74pvn tankless water heater that has worked great for5 years but it stopped working just now. Won't light, looks like there is no power to the board but I've checked that. read more Richmond water heater pilot light. Water heater thermocouple. How to bypass thermocouple. Richmond water heater pilot won't stay lit. Water heater pilot ligh...Power Vent. Uses indoor air for combustion with flexible venting options up to 100 feet. View Product. Gas. Electric. Speciality. Sep 4, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... Water heater pilot won't light. Richmond water heater, smelled for gas at end of tibe by burner and is present. Filter isn't clogged. Ignition sparks. ...1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve.Richmond water heater, pilot light won’t remain on, 6G40-36F1, Yesterday - pilot went out, relighted the pilot, pilot - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … read moreAre you running out of hot water or your hot water is only lukewarm? The most common problem which can be easily fixed is your pilot light went out if you h...You can easily determine whether the gas valve of Richmond Water Heater gets bad or not by lighting the pilot and testing the thermocouple. Let’s start with lighting the pilot. Follow the manual and attempt to light the pilot. Press the pilot knob all the way down and keep pressing the igniter button. If the pilot light doesn’t come on ...Sep 4, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ... Jun 10, 2022 · It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c... If your Richmond water heater pilot light won’t stay lit, you will have trouble getting hot water around the house. So the first thing you should do is check the thermocouple. But if the thermocouple is fine, you should check the other things I mentioned in today’s article.Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to tryIf your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ...I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.Water heater pilot won't light. Richmond water heater, smelled for gas at end of tibe by burner and is present. Filter isn't clogged. Ignition sparks. ...Jan 24, 2023 · January 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water. May 4, 2021 · Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … Water heater pilot won't light. Richmond water heater, smelled for gas at end of tibe by burner and is present. Filter isn't clogged. Ignition sparks. ...1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.Reignite the pilot light. Richmond gas heaters use a pilot light to ignite the gas heating the water. Make sure the light hasn't blown out, and if it has, use the ignition mechanism on the heater to light the pilot. Drain and clean the heater. Follow the instructions in Section 2 for draining your Richmond heater and clean the tank and all ...I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.Power Vent. Uses indoor air for combustion with flexible venting options up to 100 feet. View Product. Gas. Electric. Speciality. 5. Flex Tube Defects. This also another possible reason why your pilot’s light won’t come on. The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. This usually happens when the tube is kinked at one or many points. The pilot light is an important part of your Rheem water heater, but it might occasionally not light. Usually, relighting the light will restore your water heater’s functionality, but if the light won’t light, there’s a larger issue to address. Contents show 1 1. You Have a Blocked Gas Line 1.1 How To Fix 2 … Rheem Water Heater Pilot Light Won’t Light – Fixed Read More »I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.Power Vent. Uses indoor air for combustion with flexible venting options up to 100 feet. View Product. Gas. Electric. Speciality. You can easily determine whether the gas valve of Richmond Water Heater gets bad or not by lighting the pilot and testing the thermocouple. Let’s start with lighting the pilot. Follow the manual and attempt to light the pilot. Press the pilot knob all the way down and keep pressing the igniter button. If the pilot light doesn’t come on ...You can easily determine whether the gas valve of Richmond Water Heater gets bad or not by lighting the pilot and testing the thermocouple. Let’s start with lighting the pilot. Follow the manual and attempt to light the pilot. Press the pilot knob all the way down and keep pressing the igniter button. If the pilot light doesn’t come on ...May 7, 2023 · If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won't stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them. Mar 20, 2022 · The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article. It is able to detect flammable vapors, protecting the water heater from excessive electricity flow and damage. In case the water heater pilot light doesn’t stay lit, it is possible that the thermal switch is either damaged or tripped. 3. Faulty thermocouple. Even if you’ve replaced the thermocouple, it is still possible that the ...I am posting this video as there are many videos on YouTube explaining what to do if your pilot light doesn't remain on after igniting, but couldn't find a v...1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.

Reignite the pilot light. Richmond gas heaters use a pilot light to ignite the gas heating the water. Make sure the light hasn't blown out, and if it has, use the ignition mechanism on the heater to light the pilot. Drain and clean the heater. Follow the instructions in Section 2 for draining your Richmond heater and clean the tank and all ... . Alle gift card deals 2023

richmond water heater pilot light won

Dec 16, 2020 · We have a Rheem gas water heater model number 21V40-7P. We've just gotten the gas tank refilled, but for some reason, the pilot light went out this morning and the water heater is leaking. I'm trying … read more Jun 17, 2018 · my water heater won't stay on I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.Press and hold down the button. Listen for the click and ignition. Your igniter should light the gas directly if it is a hot surface ignition. You will know it is working if you feel the heat coming from the unit. Lighting an intermittent pilot ignition: Locate the igniter button and knob.May 4, 2021 · Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ...Mar 1, 2020 · The Solution: Straighten all kinks on the flex tube. It’s also wise to look for any visible damage that might cause gas leaks. Gas leaks will reduce the amount of gas reaching the burner. It might be the reason why your furnace pilot light keeps going out or flickering. 6. A Faulty Main Control Valve. Reopen the shutoff valve. Relight the pilot light. Turn the control valve to “on”. When the gas burner comes on, use a 50/50 dish soap/water mix to test the screw joints for air bubbles that indicate leaks. Note: When relit, the water heater pilot light flame should wrap around the thermocouple bulb.January 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water.May 7, 2023 · If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won't stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them. Reignite the pilot light. Richmond gas heaters use a pilot light to ignite the gas heating the water. Make sure the light hasn't blown out, and if it has, use the ignition mechanism on the heater to light the pilot. Drain and clean the heater. Follow the instructions in Section 2 for draining your Richmond heater and clean the tank and all ...I am posting this video as there are many videos on YouTube explaining what to do if your pilot light doesn't remain on after igniting, but couldn't find a v...It's easy to fix this water heater problem by yourself. I fixed mine and also decided to make a better video to help out more people who love DIY.- Pilot lig...May 4, 2021 · Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty.Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions for lighting do not match my heater: I see no door to open; no place to see the pilot to determine if it's litInstall a New Thermocouple. Insert the new thermocouple from the outside through the grommet or opening in the burner assembly manifold cover. Insert the thermocouple into its mounting bracket until it is fully seated or clicks into place. Position the thermocouple tip so that the pilot flame will envelop the top 3/8 to 1/2 inch of the ...my Richmond 40 gal. hot water heater that's only 2 yrs old stopped working. I relit it, and it was fine for a few hours. it went out again and I considered t...Mar 1, 2020 · The Solution: Straighten all kinks on the flex tube. It’s also wise to look for any visible damage that might cause gas leaks. Gas leaks will reduce the amount of gas reaching the burner. It might be the reason why your furnace pilot light keeps going out or flickering. 6. A Faulty Main Control Valve. .